CHTNW - SILICONE (DOT 5) BRAKE FLUID, 01779940

  • MSDS: CHTNW
  • Manufacturer: QUAKER STATE CORP
  • Product Name: SILICONE (DOT 5) BRAKE FLUID, 01779940
  • National Stock Number: 9150-00N089028
Product Identification

Product ID:SILICONE (DOT 5) BRAKE FLUID, 01779940
MSDS Date:02/25/1997
FSC:9150
NIIN:00N089028
Status Code:A
MSDS Number: CHTNW

Responsible Party
QUAKER STATE CORP
225 E JOHN CARPENTER FREEWAY
IRVING, TX 75062
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 800-562-5928

Cage: DO899

Contractor
QUAKER STATE OIL REFINING CORPORATION
OIL CITY, PA 16301 US

Telephone: 814-676-7676

Cage: DO899

Ingredients

(ORAL, RAT) >24 G/KG.

CAS: 63148-62-9

RTECS: JJ6484500

Fraction By Weight: 95%

OSHA PEL N/K

ACGIH TLV: N/K


SEBACIC ACID, BIS(2-ETHYLHEXYL) ESTER; (DECANOIC ACID,

CAS: 122-62-3

RTECS: VS1000000

Fraction By Weight: 3%

OSHA PEL N/K

ACGIH TLV: N/K


(ORAL, RAT) >1400 MG/KG.

CAS: 126-73-8

RTECS: TC7700000

Fraction By Weight: 2%

OSHA PEL 5 MG/M3

ACGIH TLV: 0.2 PPM


ANY WARNING ODOR BEING SENSED. TOXICOLOGICAL INFO

RTECS: 9999999ZZ


EXPOS TO TRIBUTYL PHOSPHATE COMPLAINED OF NAUS &

RTECS: 9999999ZZ


EDEMA & CHOLINERGIC SYMPS INCL SALIVATION, LACRIM,

RTECS: 9999999ZZ


CAPACITY FOR SKIN ABSORPTION. TRIBUTYL PHOSPHATE

RTECS: 9999999ZZ


WEAK, DYSPNEA & COMA. ETHYLENE GLYCOL CAUSED DNA

RTECS: 9999999ZZ


ABERRATIONS IN RAT BONE MARROW CELLS & SPERMATIDS.

RTECS: 9999999ZZ


MICROSOME ASSAY (AMES ASSAY). TRIBUTYL PHOSPHATE

RTECS: 9999999ZZ


MED ATTN IF SYMPTOMS PERSIST. NOTES TO MD

RTECS: 9999999ZZ


CLEAN-UP HAS BEEN COMPLETED. DO NOT ALLOW PROD

RTECS: 9999999ZZ


INHAL OF VAPORS DURING DISPOSAL OF SPILLS. REMOVE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: MAY CAUSE MOD IRRIT, INCLUDING
BURNING SENSATION, TEARING, REDNESS OR SWELLING. CAN CAUSE IMMED
PAIN, CONJ & POSS CORNEAL INJURY. SKIN: PROD MAY CAUSE IRRIT TO
SKIN. PRLNGD &/OR RPTD SKIN CONTAC T W/PROD MAY CAUSE IRRIT/DERM.
PROD CNTNS COMPONENT(S) WHICH MAY BE ABSORBED THRU SKIN. INGEST:
CAN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: CAUSE GI IRRIT, NAUS, VOMIT & DIARR.
INGEST OF SM AMT IS NOT LIKELY TO CAUSE INJURY. INGEST OF LARGER
AMTS OF PROD MAY BE HARMFUL/FATAL. INHAL: HIGH VAP/AEROSOL CONCS
MAY BE IRRIT TO RESP TR ACT. EXCESSIVE INHAL OF THIS MATL CAUSES
HDCH, SLEEPINESS, DIZZ, SLURRED SPEECH & BLURRED VISION. IF PROD IS
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH EYES W/LARGE AMTS OF WATER FOR AT LEAST 15 MIN.
GET MED ATTN IF EYE IRRIT DEVELOPS OR PERSISTS. SKIN: REMOVE CONTAM
CLTHG. WASH AFFECTED AREA W/MILD SOAP & WATER. GET MED ATTN IF SKIN
DISO RDER DEVELOPS. INGEST: IF MATL IS SWALLOWED, GET IMMED MED
ATTN OR ADVICE. DO NOT INDUCE VOMIT UNLESS INSTRUCTED TO DO TO BY
MED PERS. INHAL: IF AFFECTED, REMOVE INDIVIDUAL TO FRESH AIR. GET
(ING 11)

Fire Fighting

Flash Point:>210F,>99C
Extinguishing Media:USE WATER SPRAY, DRY CHEMICAL, FOAM OR CARBON
DIOXIDE TO EXTINGUISH THE FIRE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . FIREFIGHTERS SHOULD AVOID INHALING ANY COMBUSTION
PRODUCTS.
Unusual Fire/Explosion Hazard:PRODUCT IS NON-FLAMMABLE. COMBUSTION OF
PROD MAY PRDCE SMOKE, FORMALDEHYDE, SILICON DIOXIDE, OXIDES OF
NITROGEN, CARBON MONOXIDE, CARBON DIOXIDE & LOW (SUPDAT)

Accidental Release

Spill Release Procedures:CONTAIN DISCHARGED MATL. ABSORB WITH INERT
ABSORBENT SUCH AS DRY CLAY, SAND OR DIATOMACEOUS EARTH. SCOOP UP
USED ABSORB INTO DRUMS OR OTHER APPROP CNTNR. PERSONS NOT WEARING
APPROP PROT EQUIP SHOULD B E EXCLUDED FROM AREA OF SPILL UNTIL (ING
12)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP THE CONTAINER TIGHTLY CLOSED AND
IN A COOL, WELL-VENTILATED PLACE. DO NOT STORE THIS MATERIAL IN
OPEN OR UNLABELED CONTAINERS.
Other Precautions:AVOID GETTING THIS MATERAIL INTO CONTACT WITH YOUR
EYES. AVOID PRLNGD/RPTD SKIN CONTACT W/MATERIAL. AVOID BRTHG MISTS
OR VAPORS. USE THIS PRODUCT WITH ADEQUATE VENTILATION. WASH
THOROUGHLY AFTER HANDL ING.

Exposure Controls

Respiratory Protection:IF VENTILATION IS NOT SUFFICIENT TO EFFECTIVELY
PREVENT BUILDUP OF DUSTS, APPROPRIATE NIOSH APPROVED RESPIRATORY
PROTECTION MUST BE PROVIDED.
Ventilation:USE GENERAL VENTILATION AND LOCAL EXHAUST WHERE POSSIBLE IN
CONFINED OR ENCLOSED SPACES.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: MOLECULAR WEIGHT HYDROCARBONS. HAZ DECOMP PRODS: MOLECULAR
WEIGHT HYDROCARBONS. EFTS OF OVEREXP: HEATED OVER 70C(155F), ESP IN
PRESENCE OF WATER, HYDROGEN SULFIDE MAY BE RELEASED. HYDROGEN
SULFIDE IS IRRIT TO EYES & RESP SYS. CONTINUED OVEREXP MAY CAUSE
RESP COLLAPSE, COMA & DEATH W/OUT NECESSARILY (ING 4)

Chemical Properties

Vapor Pres:LOW
Spec Gravity:0.95
Solubility in Water:SOLUBLE
Appearance and Odor:PURPLE LIQUID; SLIGHT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
THIS PRODUCT MAY REACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT, FORMATION OF MISTS.
Hazardous Decomposition Products:DECOMP MAY PRDCE FORMALDEHYDES, OXIDES
OF NITROGEN, SILICON DIOXIDE, CARBON MONOXIDE, CARBON DIOXIDE & LOW
(SUPDAT)

Disposal

Waste Disposal Methods:NO COMPONENTS ARE IDENTIFIED AS HAZARDOUS WASTE.
DO NOT ALLOW THIS MATERIAL TO DRAIN INTO SEWERS/WATER SUPPLIES.
DISPOSE OF WASTE MATERIAL ACCORING TO LOCAL, STATE, FEDERAL &
PROVINCIAL ENVIRONMENTAL REGULATIONS. MATERIAL SHOULD BE RECYCLED
IF POSS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.